How do I write my own mechanism command?
Write a command, an AdvantageKit IO class or a state machine that sets a mechanism's target with the setpoint functions.
The built-in commands, run, runTo, set and setVoltage, cover most needs. When they do not, for example when the target needs extra logic every loop, when an AdvantageKit IO class sets it, or when a state machine decides it, set the target yourself with the mechanism's setpoint functions. This page shows each case.
Controlling a mechanism lists every setpoint function for each mechanism.

The rules
A setpoint function sets the target and returns at once. It is not a command, and it does not require the subsystem. Call it from inside a command that does, so two pieces of code never fight over the motor.
Position and velocity setpoint functions start the closed loop if it was stopped. Voltage and duty cycle ones stop it. You do not need to manage the loop when you use them.
Starting a stopped loop resets it to where the mechanism is now: the PID controller, the motion profile and the LQR's estimate start fresh. On a loop that is already running, starting it does nothing, so calling
setMechanismPositionSetpoint(...)every loop is fine.The motor keeps its last request when your command ends, as with the built-in commands. See When mechanism commands end.
A command with extra logic
This command follows a target from a supplier, and adds 5 degrees while the arm is below level.
getArm() is a getter you add to ArmSubsystem that returns its YAMS Arm field. The command never finishes, so bind it with whileTrue, or use it as a default command.
Commands v3 has no command classes with execute(). Write the same logic as a while (true) coroutine in your ArmMechanism, where arm is its YAMS Arm field:
run(...) on a Mechanism requires that mechanism, so no other command drives the arm at the same time.
To end a command like this when the arm arrives, check arm.isNear(goal, tolerance): in Commands v2 return it from isFinished(), and in Commands v3 make it the while condition.
An AdvantageKit IO class
An IO class is called by the subsystem, which owns the requirement, so it uses the setpoint functions directly. Take Measure types, not double:
AdvantageKit Integration builds the whole IO layer.
A state machine (Commands v3)
WPILib's Commands v3 has a state machine built in, org.wpilib.command3.StateMachine. Each state runs one command, and transitions say when to move to another state. The state machine cancels the current state's command and starts the next one for you.
The imports are org.wpilib.command3.StateMachine, org.wpilib.command3.StateMachine.State and java.util.function.BooleanSupplier. Schedule it like any other command. A Trigger is a BooleanSupplier, so buttons can be the conditions:
How it behaves:
setInitialState(state)is required. Without it the state machine throws when it starts.when(condition)fires when the condition turns from false to true while that state is active. A button already held when the state starts does not count until it is released and pressed again.If two transitions fire in the same loop, the first one declared wins.
The state machine itself requires nothing; each state's command requires the arm. Another command that takes the arm cancels the running state, and with no
whenComplete()transition from that state, the state machine exits.A state whose command ends by itself, with no
whenComplete()transition, also ends the state machine. TheseholdAtcommands never end, so this one runs until it is canceled.
Driving the motor controller yourself
You can skip the mechanism and call the SmartMotorController from arm.getMotorController(), with setPosition(...), setVelocity(...), setVoltage(...) or setDutyCycle(...). Unlike the setpoint functions, these calls do not start or stop the closed loop, so your command calls startClosedLoopController() or stopClosedLoopController() once when it starts. How do I control a mechanism without a mechanism class? shows this in full.

Read more
When mechanism commands end explains how your command fits with runTo and the default command.
Last updated