How do I tune my elevator in rotations instead of meters?
Goal: keep the closed loop controller (its error, kP and profile limits) in rotations, while still reading positions and speeds in meters.
What is linear closed loop control?
YAMS's closed loop controller can work in one of two units:
Angle based (rotations). The error is in rotations,
kPis in volts per rotation, and profile limits are in rotations per second.Distance based, or linear (meters). The error is in meters,
kPis in volts per meter, and profile limits are in meters per second.

The units change what your gains mean: a kP of 4 volts per meter is a very different controller from 4 volts per rotation.
When is it on?
It is off by default. Setting a circumference (withWheelDiameter, withDrumRadius and so on) does not turn it on; that only lets YAMS report distances. These SmartMotorControllerConfig calls turn it on:
withFeedforward(ElevatorFeedforward)orwithSimFeedforward(ElevatorFeedforward)withTrapezoidalProfile(LinearVelocity, LinearAcceleration)(a profile in meters per second)withTrapezoidalProfile(LinearAcceleration, Velocity<LinearAccelerationUnit>)withExponentialProfile(Voltage, DCMotor, Mass, Distance)(the elevator form)
So a typical elevator config uses linear closed loop control without you asking for it.
When would I turn it off?
You tuned an elevator in rotations and want to keep those gains.
You are copying gains from a tool or another robot that works in rotations.
You use an
ElevatorFeedforwardfor a mechanism that you want to control in rotations.
Turning it off does not stop YAMS reporting distances. getMeasurementPosition() and getMeasurementVelocity() still return meters, as long as the circumference is set.
Make the profile limits angular
If the config has a motion profile, its limits must now be angular too, for example withTrapezoidalProfile(RotationsPerSecond.of(2), RotationsPerSecondPerSecond.of(4)), placed before the false. Your gains are now in volts per rotation, so tune kP again.
Check it: the code builds, and a commanded move is neither much softer nor much harsher than you expect.
Check it
Deploy (or start the simulation) and command a height.
Under NetworkTables > Mechanisms, the motor's
closedloop/setpoint/positionis now in rotations, whilemeasurement/positionis still in meters.
If it did not work
The setpoint is still in meters. A call from the list above comes after
withLinearClosedLoopController(false). Move thefalseto the end of the chain.The elevator is much too soft or too aggressive. Your gains were tuned in the other unit. Tune
kPagain; see Troubleshooting.
Read more
Command the elevator in meters: How do I set an elevator's target height?
Last updated
Was this helpful?