> For the complete documentation index, see [llms.txt](https://yams.yassrobotics.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://yams.yassrobotics.com/documentation/how-to-simulation-and-logging/how-do-i-enable-battery-discharge-simulation.md).

# How do I enable battery discharge simulation?

**Goal:** make the simulated battery run down over a match, so the voltage sags harder near the end than at the start, as a real battery does.

By default the simulated battery sags while your mechanisms draw current, but it never runs down: every moment of the run starts from a full 12 V battery. Discharge simulation adds the battery's **state of charge**, how full it is from 1 (full) to 0 (empty). As your mechanisms draw current, the charge goes down. A battery that is less full rests at a lower voltage, and its **internal resistance**, which makes the voltage sag under load, goes up. So late in a long simulated run, the same load sags the voltage further.

For why YAMS models one shared battery at all, see [Battery Simulation](https://yams.yassrobotics.com/documentation/understanding/battery-simulation.md).

## Turn on discharge modeling

Call `enableDischarge(...)` once, early on, with the battery's capacity in amp-hours (how much charge it holds), its voltage when full, and its internal resistance when full. The `Robot` constructor is a good place for it. A fresh 18 Ah competition battery is a reasonable default if you have no measured numbers for your own.

{% tabs %}
{% tab title="Java" %}
{% code title="Robot.java (fragment)" %}

```java
import static org.wpilib.units.Units.MilliOhms;
import static org.wpilib.units.Units.Volts;

import yams.core.motorcontrollers.simulation.BatterySim;

public Robot() {
  // 18 Ah, 12.9 V and 20 milliohms when full.
  BatterySim.enableDischarge(18.0, Volts.of(12.9), MilliOhms.of(20));
}
```

{% endcode %}
{% endtab %}

{% tab title="C++" %}
{% code title="cpp/Robot.cpp (fragment)" %}

```cpp
#include <yams/motorcontrollers/simulation/BatterySim.hpp>

Robot::Robot() {
  // 18 Ah, 12.9 V and 20 milliohms when full.
  yams::motorcontrollers::simulation::BatterySim::EnableDischarge(
      18.0, wpi::units::volt_t{12.9}, wpi::units::ohm_t{0.020});
}
```

{% endcode %}
{% endtab %}
{% endtabs %}

{% hint style="warning" %}
Discharge modeling only affects simulation. On a real robot `BatterySim` is never used: the SystemCore reports the real battery voltage, so this call does nothing there.
{% endhint %}

<figure><img src="https://1354553280-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FZM0CFmYiQzcrY4zDcTtZ%2Fuploads%2Fgit-blob-2f3c0455fba73fccc85b012549c367bc6a649c39%2Fbattery-sim-discharge.png?alt=media" alt="Two graphs of the default discharge model. Resting voltage against state of charge falls slowly from 12.9 volts at full to 12.0 volts at 20 percent, then steeply to 9 volts when empty. Usable capacity against sustained current falls from 100 percent at 0.9 amps to 60 percent at 54 amps. Internal resistance rises from 20 milliohms when full to 60 milliohms when empty"><figcaption><p>The default discharge curves.</p></figcaption></figure>

## Make sure your mechanisms report accurate current draw

The simulated battery only runs down as fast as the current your mechanisms draw, and that comes from each mechanism's physics simulation. If a mechanism's moment of inertia is guessed rather than measured, its simulated current draw, and so how fast it drains the battery, will be off. Set a real one on each `SmartMotorControllerConfig` with `withMomentOfInertia(...)` before relying on discharge numbers: see [MOI](https://yams.yassrobotics.com/documentation/understanding/turrets-wrists.md#moment-of-inertia) for how.

<figure><img src="https://1354553280-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FZM0CFmYiQzcrY4zDcTtZ%2Fuploads%2Fgit-blob-5676fc440147bf970eeca17663417c43d4f9a903%2Fbattery-sim-mechanisms.png?alt=media" alt="Six sketches of current over time. Arm: spikes when it starts and stops, then a steady draw to hold against gravity. Elevator: largest going up, steady to hold a height. Flywheel, shooter, rollers: very large while spinning up, small at speed, a bump on every shot. Pivot, turret, wrist: short bursts when starting and stopping. Swerve drive: eight motors, usually the largest draw. All together: the draws add up and overlapping peaks cause the deepest sag"><figcaption><p>When each kind of mechanism draws current.</p></figcaption></figure>

## Reset between runs (optional)

The simulated battery keeps its charge from one simulated match to the next, as a real battery does. To start every simulated match or unit test from a full battery, call `resetDischarge()` at the start of it: in the setup of your unit tests, or wherever you reset robot state between simulated matches. `disableDischarge()` turns discharge modeling back off.

{% tabs %}
{% tab title="Java" %}
{% code title="A unit test (fragment)" %}

```java
import org.junit.jupiter.api.BeforeEach;
import yams.core.motorcontrollers.simulation.BatterySim;

@BeforeEach
void setup() {
  BatterySim.resetDischarge();
}
```

{% endcode %}
{% endtab %}

{% tab title="C++" %}
{% code title="A unit test (fragment)" %}

```cpp
#include <yams/motorcontrollers/simulation/BatterySim.hpp>

// At the start of each test.
yams::motorcontrollers::simulation::BatterySim::ResetDischarge();
```

{% endcode %}
{% endtab %}
{% endtabs %}

## Read the state of charge for telemetry (optional)

`getStateOfCharge()` returns the charge from `0` (empty) to `1` (full). Publish it every loop to watch the battery run down over a simulated match. YAMS sets the simulated battery voltage but does not publish it, so publish that too: it is what `RobotController` reports, in simulation as on the robot.

{% tabs %}
{% tab title="Java" %}
{% code title="Robot.java (fragment)" %}

```java
import static org.wpilib.units.Units.Volts;

import org.wpilib.system.RobotController;
import org.wpilib.telemetry.Telemetry;
import yams.core.motorcontrollers.simulation.BatterySim;

@Override
public void robotPeriodic() {
  // ...
  Telemetry.log("Battery/StateOfCharge", BatterySim.getStateOfCharge());
  Telemetry.log("Battery/Voltage", RobotController.getMeasureBatteryVoltage().in(Volts));
}
```

{% endcode %}
{% endtab %}

{% tab title="C++" %}
{% code title="cpp/Robot.cpp (fragment)" %}

```cpp
#include <wpi/system/RobotController.hpp>
#include <wpi/telemetry/Telemetry.hpp>
#include <yams/motorcontrollers/simulation/BatterySim.hpp>

void Robot::RobotPeriodic() {
  // ...
  wpi::telemetry::Log("Battery/StateOfCharge",
                      yams::motorcontrollers::simulation::BatterySim::GetStateOfCharge());
  wpi::telemetry::Log("Battery/Voltage", wpi::RobotController::GetBatteryVoltage().value());
}
```

{% endcode %}
{% endtab %}
{% endtabs %}

## Replace the state-of-charge curve (optional)

`enableDischarge(...)` lowers the resting voltage along a curve for a typical FRC sealed lead-acid battery: flat through most of the charge, then dropping quickly near empty. To model a different battery, such as a well-used one that sags earlier, or one you measured with a load tester, call `replaceSOCInterpolation(...)` with your own curve of state of charge to voltage, **before** `enableDischarge(...)`.

{% tabs %}
{% tab title="Java" %}
{% code title="Robot.java (fragment)" %}

```java
import static org.wpilib.units.Units.MilliOhms;
import static org.wpilib.units.Units.Volts;

import org.wpilib.math.interpolation.InterpolatingDoubleTreeMap;
import yams.core.motorcontrollers.simulation.BatterySim;

// State of charge, then the resting voltage at that charge.
InterpolatingDoubleTreeMap wornBatteryCurve = new InterpolatingDoubleTreeMap();
wornBatteryCurve.put(0.00, 8.0);
wornBatteryCurve.put(0.05, 9.5);
wornBatteryCurve.put(0.10, 10.5);
wornBatteryCurve.put(0.20, 11.2);
wornBatteryCurve.put(0.40, 11.6);
wornBatteryCurve.put(0.60, 11.9);
wornBatteryCurve.put(0.80, 12.2);
wornBatteryCurve.put(0.90, 12.4);
wornBatteryCurve.put(1.00, 12.6);

BatterySim.replaceSOCInterpolation(wornBatteryCurve);
// replaceSOCInterpolation swaps the curve as soon as it is called. Calling it first means discharge uses your curve from the start.
BatterySim.enableDischarge(15.0, Volts.of(12.6), MilliOhms.of(28));
```

{% endcode %}
{% endtab %}

{% tab title="C++" %}
{% code title="cpp/Robot.cpp (fragment)" %}

```cpp
#include <map>

#include <yams/motorcontrollers/simulation/BatterySim.hpp>

using yams::motorcontrollers::simulation::BatterySim;

// State of charge, then the resting voltage at that charge.
std::map<double, double> wornBatteryCurve{
    {0.00, 8.0},  {0.05, 9.5},  {0.10, 10.5}, {0.20, 11.2}, {0.40, 11.6},
    {0.60, 11.9}, {0.80, 12.2}, {0.90, 12.4}, {1.00, 12.6},
};

BatterySim::ReplaceSOCInterpolation(wornBatteryCurve);
// ReplaceSOCInterpolation swaps the curve as soon as it is called. Calling it first means discharge uses your curve from the start.
BatterySim::EnableDischarge(15.0, wpi::units::volt_t{12.6}, wpi::units::ohm_t{0.028});
```

{% endcode %}
{% endtab %}
{% endtabs %}

{% hint style="info" %}
Cover the whole range of charge, from `0` to `1`. Outside the points you give, the voltage stays at the nearest point's, so a curve missing the low or high end will not sag realistically there. See [Custom discharge curves](https://yams.yassrobotics.com/documentation/understanding/battery-simulation.md#custom-discharge-curves) for choosing the points.
{% endhint %}

## Replace the capacity derating curve (optional)

A lead-acid battery gives fewer amp-hours the faster it is drained (the Peukert effect). `enableDischarge(...)` accounts for this with a curve of sustained current to the fraction of the capacity you get, averaged from real FRC battery testing. If you measured your own battery, call `replaceCapacityDerating(...)` with your curve, **before** `enableDischarge(...)`.

{% tabs %}
{% tab title="Java" %}
{% code title="Robot.java (fragment)" %}

```java
import static org.wpilib.units.Units.MilliOhms;
import static org.wpilib.units.Units.Volts;

import org.wpilib.math.interpolation.InterpolatingDoubleTreeMap;
import yams.core.motorcontrollers.simulation.BatterySim;

// Sustained current in amps, then the fraction of the capacity you get at that current.
InterpolatingDoubleTreeMap measuredDerating = new InterpolatingDoubleTreeMap();
measuredDerating.put(0.9, 1.000);
measuredDerating.put(20.0, 0.80);
measuredDerating.put(40.0, 0.65);
measuredDerating.put(60.0, 0.55);

BatterySim.replaceCapacityDerating(measuredDerating);
// replaceCapacityDerating swaps the curve as soon as it is called. Calling it first means discharge uses your curve from the start.
BatterySim.enableDischarge(18.0, Volts.of(12.9), MilliOhms.of(20));
```

{% endcode %}
{% endtab %}

{% tab title="C++" %}
{% code title="cpp/Robot.cpp (fragment)" %}

```cpp
#include <map>

#include <yams/motorcontrollers/simulation/BatterySim.hpp>

using yams::motorcontrollers::simulation::BatterySim;

// Sustained current in amps, then the fraction of the capacity you get at that current.
std::map<double, double> measuredDerating{{0.9, 1.000}, {20.0, 0.80}, {40.0, 0.65}, {60.0, 0.55}};

BatterySim::ReplaceCapacityDerating(measuredDerating);
// ReplaceCapacityDerating swaps the curve as soon as it is called. Calling it first means discharge uses your curve from the start.
BatterySim::EnableDischarge(18.0, wpi::units::volt_t{12.9}, wpi::units::ohm_t{0.020});
```

{% endcode %}
{% endtab %}
{% endtabs %}

See [Capacity derating](https://yams.yassrobotics.com/documentation/understanding/battery-simulation.md#capacity-derating) for where the default curve comes from.

## Check it

1. Publish the state of charge and the battery voltage as in [Read the state of charge for telemetry](#read-the-state-of-charge-for-telemetry-optional), start the simulation, and graph `Battery/StateOfCharge` and `Battery/Voltage` in AdvantageScope.
2. Run your mechanisms hard for a minute or two: spin up a shooter, drive the swerve back and forth.
3. `Battery/StateOfCharge` should start at 1 and fall steadily while mechanisms run, and stay put while they are idle. `Battery/Voltage` should sag more under the same load late in the run than at the start, and its resting value should creep down.

If the state of charge never moves, `enableDischarge(...)` was not called. If it barely moves, check the moments of inertia: see [Make sure your mechanisms report accurate current draw](#make-sure-your-mechanisms-report-accurate-current-draw).

## Related pages

* [Battery Simulation](https://yams.yassrobotics.com/documentation/understanding/battery-simulation.md), the full explanation of the shared battery model and why it matters
* [MOI](https://yams.yassrobotics.com/documentation/understanding/turrets-wrists.md#moment-of-inertia), accurate current draw starts with an accurate moment of inertia
* [Limiting Power Consumption](https://yams.yassrobotics.com/documentation/how-to-motor-controllers-and-sensors/limiting-power-consumption.md)


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://yams.yassrobotics.com/documentation/how-to-simulation-and-logging/how-do-i-enable-battery-discharge-simulation.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.