> For the complete documentation index, see [llms.txt](https://yams.yassrobotics.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://yams.yassrobotics.com/documentation/reference/editor/config/limits-and-protection.md).

# Limits and protection

These options stop a mechanism or a motor from hurting itself or the rest of the robot.

{% hint style="warning" %}
Not every option on this page is supported on every motor controller. Each option has a table showing where it works, and an option a controller cannot do throws a `SmartMotorControllerConfigurationException` or an `IllegalArgumentException` at startup. Each option says which. The [config overview](https://yams.yassrobotics.com/documentation/reference/editor/config.md#not-every-option-works-on-every-motor-controller) lists them all together.
{% endhint %}

## `withSoftLimits`

The range the mechanism is allowed to move through.

<figure><img src="https://1354553280-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FZM0CFmYiQzcrY4zDcTtZ%2Fuploads%2Fgit-blob-b4934b97bacb73e6df57d1dc94e5c782997037e8%2Fsmc-soft-limits.png?alt=media" alt="A bar showing a mechanism&#x27;s travel between two hard stops, with a lower and an upper soft limit a little inside them. The mechanism may move between the soft limits. A setpoint asked for beyond the upper limit is moved back to the limit."><figcaption><p>Soft limits sit a little inside the hard stops.</p></figcaption></figure>

```java
.withSoftLimits(Degrees.of(-20), Degrees.of(100))
.withSoftLimits(Meters.of(0), Meters.of(1.2))     // needs a circumference
```

The lower limit must be below the upper limit. Soft limits cannot be combined with [continuous wrapping](https://yams.yassrobotics.com/documentation/reference/editor/config/closed-loop-control.md#withcontinuouswrapping): setting both throws a `SmartMotorControllerConfigurationException`, in either order. They can be combined with [`withWrapping`](https://yams.yassrobotics.com/documentation/reference/editor/config/encoders.md#withwrapping), which only sets the range an absolute encoder reads.

Soft limits rely on the encoder being right. If the mechanism does not start where the encoder thinks it does, the limits are in the wrong place: see [starting position](https://yams.yassrobotics.com/documentation/reference/editor/config/encoders.md#withstartingposition).

**Only in closed loop mode.** Soft limits are only enforced with [`withControlMode(ControlMode.CLOSED_LOOP)`](https://yams.yassrobotics.com/documentation/reference/editor/config/motor-basics.md#withcontrolmode), the default. They are set on the motor controller and stop any output that would go past them, including a voltage or duty cycle. A Thrifty Nova has one enable for both limits, so it needs both an upper and a lower limit: setting only one throws a `SmartMotorControllerConfigurationException`. An A301 has no soft limits of its own, so its loop on the SystemCore enforces them: a position setpoint past a limit is moved to the limit, but a voltage or duty cycle is not stopped.

| TalonFX                     | TalonFXS                    | SPARK MAX / Flex            | Thrifty Nova                                      | A301                                                     |
| --------------------------- | --------------------------- | --------------------------- | ------------------------------------------------- | -------------------------------------------------------- |
| ⚠️ only in closed loop mode | ⚠️ only in closed loop mode | ⚠️ only in closed loop mode | ⚠️ only in closed loop mode, with both limits set | ⚠️ closed loop setpoints only, not voltage or duty cycle |

## `withStatorCurrentLimit` and `withSupplyCurrentLimit`

`withStatorCurrentLimit` limits the current through the motor, which limits its torque and heat. `withSupplyCurrentLimit` limits the current drawn from the battery, which protects the breaker and the battery voltage.

<figure><img src="https://1354553280-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FZM0CFmYiQzcrY4zDcTtZ%2Fuploads%2Fgit-blob-75f89f9c2884411442900d9c21b991c13d9e279d%2Fpower-supply-stator.png?alt=media" alt="Supply current flows from the battery to the motor controller, and stator current flows from the motor controller through the motor. A supply limit protects the battery and breaker, a stator limit protects the motor and limits torque"><figcaption><p>Supply current and stator current.</p></figcaption></figure>

```java
.withStatorCurrentLimit(Amps.of(40))
.withSupplyCurrentLimit(Amps.of(30))
```

`withOutputCurrentLimit` is another name for `withStatorCurrentLimit`, and `withInputCurrentLimit` is another name for `withSupplyCurrentLimit`. They do exactly the same thing.

[How do I limit power consumption?](https://yams.yassrobotics.com/documentation/how-to-motor-controllers-and-sensors/limiting-power-consumption.md#set-a-starting-limit-on-each-motor) explains how to choose them, with starting limits for common motors, and how to test them against the [battery simulation](https://yams.yassrobotics.com/documentation/understanding/battery-simulation.md).

**Not supported everywhere.** `withSupplyCurrentLimit` is not available on SPARKs. The A301 has no current limits at all: either one throws a `SmartMotorControllerConfigurationException`.

| TalonFX | TalonFXS | SPARK MAX / Flex                                                                           | Thrifty Nova | A301 |
| ------- | -------- | ------------------------------------------------------------------------------------------ | ------------ | ---- |
| ✅       | ✅        | ⚠️ stator limit only: a supply limit throws a `SmartMotorControllerConfigurationException` | ✅            | ❌    |

## `withOpenLoopRampRate` and `withClosedLoopRampRate`

`withOpenLoopRampRate` and `withClosedLoopRampRate` set the shortest time the output may take to go from zero to full.

<figure><img src="https://1354553280-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FZM0CFmYiQzcrY4zDcTtZ%2Fuploads%2Fgit-blob-bc32dd1cff426cef59e9f2d76b723ed744645101%2Fpower-ramp-rate.png?alt=media" alt="A graph of output against time. Without a ramp rate the output jumps to full at once. With a ramp rate it rises in a straight line over the ramp time"><figcaption><p>The output with and without a ramp rate.</p></figcaption></figure>

```java
.withOpenLoopRampRate(Seconds.of(0.25))
.withClosedLoopRampRate(Seconds.of(0.1))
```

A ramp rate is the last thing to reach for. It slows everything the motor does, including the closed loop controller's reactions. [Lower the biggest load first](https://yams.yassrobotics.com/documentation/how-to-motor-controllers-and-sensors/limiting-power-consumption.md#lower-the-biggest-load-first) lists what to try first.

**Not supported everywhere.** The A301 has no ramp rates: either one throws a `SmartMotorControllerConfigurationException`.

| TalonFX | TalonFXS | SPARK MAX / Flex | Thrifty Nova                                                                                         | A301 |
| ------- | -------- | ---------------- | ---------------------------------------------------------------------------------------------------- | ---- |
| ✅       | ✅        | ✅                | ⚠️ one ramp rate for both: two different values throw a `SmartMotorControllerConfigurationException` | ❌    |

## `withVoltageCompensation`

Scales the output so a duty cycle means the same voltage whatever the battery voltage is.

<figure><img src="https://1354553280-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FZM0CFmYiQzcrY4zDcTtZ%2Fuploads%2Fgit-blob-ad0869e5e52f1cbfe629b9969bd258f704d0ff1d%2Fsmc-voltage-compensation.png?alt=media" alt="Two panels comparing a 50 percent output at a 12.6 volt and a 10.5 volt battery. Without voltage compensation the motor gets 6.3 volts and then 5.25 volts, so the mechanism slows as the battery drains. With compensation to 12 volts it gets 6 volts both times."><figcaption><p>A 50% output at two battery voltages.</p></figcaption></figure>

```java
.withVoltageCompensation(Volts.of(12))
```

**Not supported everywhere.** It throws an `IllegalArgumentException` on a TalonFX or TalonFXS, and a `SmartMotorControllerConfigurationException` on an A301. Use a voltage request instead of a duty cycle on those.

| TalonFX | TalonFXS | SPARK MAX / Flex | Thrifty Nova | A301 |
| ------- | -------- | ---------------- | ------------ | ---- |
| ❌       | ❌        | ✅                | ✅            | ❌    |

## `withTemperatureCutoff`

Stops the closed loop controller driving the motor once it reaches a temperature.

<figure><img src="https://1354553280-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FZM0CFmYiQzcrY4zDcTtZ%2Fuploads%2Fgit-blob-24263d80df554541c4bf12ba85717aa6911ed49f%2Fsmc-temperature-cutoff.png?alt=media" alt="A graph against time. The motor temperature climbs until it reaches the cutoff temperature. At that moment the closed loop output drops to zero volts, the motor stops driving, and the temperature falls."><figcaption><p>The output drops to zero at the cutoff temperature.</p></figcaption></figure>

```java
.withTemperatureCutoff(Celsius.of(80))
```

While the motor is at or above the cutoff, the closed loop output is zero, so a mechanism that was being held up will drop. Treat it as a last resort and fix the cause with [current limits](https://yams.yassrobotics.com/documentation/how-to-motor-controllers-and-sensors/limiting-power-consumption.md) or gearing.

{% hint style="danger" %}
On a SPARK MAX, SPARK Flex or Thrifty Nova with a **trapezoidal** position profile, or a PID alone, the cutoff is rejected: the loop runs on the motor controller, and the cutoff is only checked by the loop on the SystemCore. Use an exponential profile if you rely on the cutoff.
{% endhint %}

**Not supported everywhere.** The cutoff is enforced by the closed loop running on the SystemCore, so it only works where the loop runs there. An [LQR controller](https://yams.yassrobotics.com/documentation/understanding/lqr-controllers.md) always runs there, so the cutoff works with LQR on every motor controller. An A301's loop always runs there, so on an A301 it works in closed loop mode.

| TalonFX                                                                                                        | TalonFXS                                                                                                       | SPARK MAX / Flex                                                                                                                         | Thrifty Nova                                                                                                                                                                                                           | A301                        |
| -------------------------------------------------------------------------------------------------------------- | -------------------------------------------------------------------------------------------------------------- | ---------------------------------------------------------------------------------------------------------------------------------------- | ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | --------------------------- |
| ⚠️ only with an [LQR controller](https://yams.yassrobotics.com/documentation/understanding/lqr-controllers.md) | ⚠️ only with an [LQR controller](https://yams.yassrobotics.com/documentation/understanding/lqr-controllers.md) | ⚠️ only with an exponential profile or an [LQR controller](https://yams.yassrobotics.com/documentation/understanding/lqr-controllers.md) | ⚠️ only when the loop runs on the SystemCore, such as with an exponential profile, a velocity trapezoidal profile or an [LQR controller](https://yams.yassrobotics.com/documentation/understanding/lqr-controllers.md) | ⚠️ only in closed loop mode |

## Code reference

* [`SmartMotorControllerConfig`](https://javadocs.yassrobotics.com/yams/yams/core/motorcontrollers/SmartMotorControllerConfig.html)


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://yams.yassrobotics.com/documentation/reference/editor/config/limits-and-protection.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.