How YAMS drives a motor

This page explains the ideas every other page assumes that you already know. Read it once before the tutorials, and come back when a word on another page is new.

  • Three layers of YAMS code

  • Definitions for:

    • A rotor according to YAMS

    • Mechanism

    • Measurement

  • Open and closed loops

  • Units for gains

Three layers

Every YAMS mechanism is built from the same three layers, from the motor up.

  1. The motor controller. The vendor's object, such as a SparkMax or a TalonFX, talks to the hardware. YAMS wraps it in a SmartMotorController (a SparkWrapper, TalonFXWrapper, TalonFXSWrapper, NovaWrapper or A301Wrapper), and you describe how the motor should behave in a SmartMotorControllerConfig: gearing, gains, limits and encoders. The config is written the same way for every vendor.

  2. The mechanism. An Arm, Elevator, Pivot or FlyWheel takes the SmartMotorController and a mechanism config (ArmConfig, ElevatorConfig and so on) that says what the mechanism is: its length, mass and hard stops. It gives you commands such as arm.run(Degrees.of(45)), simulates the physics and draws the mechanism on the dashboard.

  3. The subsystem. In Commands v2 a SubsystemBase holds the mechanism and hands its commands to the rest of the robot. In Commands v3 a class that implements Mechanism does the same job. Keep at most one YAMS mechanism in each, so live tuning can find it.

A diagram. A mechanism config, which says what the mechanism is, such as its length, mass, hard stops and how it is drawn, and a SmartMotorControllerConfig, which says how its motor behaves, such as gearing, PID, feedforward, soft limits and current, both go into the mechanism class. The mechanism then drives the simulation's physics and Mechanism2d, and the real robot's commands and telemetry.
Two configs go into one mechanism.

You can skip layer 2 and command a SmartMotorController yourself: see How do I control a mechanism without a mechanism class?

Rotor, mechanism and measurement

YAMS measures a motor's movement in three places. These words mean the same thing on every page.

An exploded NEO motor, gearbox stages, output shaft and wheel. The rotor is the NEO's own shaft, the mechanism is the output shaft after the gearbox, and the measurement is the wheel's rim. Rotor and mechanism are angles and angular velocities; the measurement is a distance and a linear velocity.
Rotor, mechanism and measurement.
  • Rotor is the motor's own shaft, before any gearing.

  • Mechanism is the output after the gearing: an arm's pivot, an elevator's drum, a flywheel's axle. YAMS reports positions as mechanism angles, such as Degrees.of(90) for an arm.

  • Measurement is the distance the mechanism moves in a line, such as an elevator's height in meters. It needs the mechanism circumference: one mechanism rotation moves one circumference.

withGearing tells YAMS how many rotor rotations make one mechanism rotation, so you only ever think in mechanism units.

Engineering Note

A rotor is the rotating part of an electric motor. It sits inside the stator, and turns when it inteacts with the magnetic field produced by the stator. The rotor is connected to the motor shaft. A motor shaft is a solid steel rod running through the center of the rotor. The shaft then transfers the mechanical motion to the load. in the above documentation, the shaft is incorrectly called a rotor...

"I'm not changing the entire API because I called a shaft, a rotor and you don't like it!" ~nstrike

Open loop and closed loop

Two panels. In OPEN_LOOP your code sends volts or duty cycle straight to the motor and no PID, feedforward or profile runs. In CLOSED_LOOP, the default, your code sends a setpoint to the PID, feedforward and profile, which drive the motor using the encoder position and velocity.
Open loop sends an output straight to the motor. Closed loop drives to a setpoint.
  • Open loop sends a voltage or a duty cycle (a fraction of full output, from -1 to 1) straight to the motor. Nothing checks where the mechanism ends up. Commands such as arm.set(0.2) and arm.setVoltage(Volts.of(2)) are open loop.

  • Closed loop takes a setpoint, the position or speed you want, and keeps adjusting the voltage until the encoder says the mechanism is there. It adds three parts: a feedforward that predicts the voltage the move needs, a PID controller that corrects the error left over, and an optional motion profile that slides the setpoint there smoothly. arm.run(Degrees.of(45)) is closed loop.

withControlMode chooses between them. ControlMode.CLOSED_LOOP is the default, and it still lets you send voltages.

Where the loop runs

The closed loop runs either on the motor controller itself, every millisecond, or on the SystemCore, every 20 ms by default. Which one depends on the motor controller and the options you pick: a TalonFX or Thrifty Nova runs PID and trapezoidal profiles itself, while an LQR runs on the SystemCore on every motor controller, and an A301, which has no closed loop of its own, runs everything on the SystemCore. You do not call anything either way. It matters for a few options, and for tuning: gains found with the loop in one place do not carry over to the other. Where the loop runs has the full table of options.

Units of your gains

Write every gain in mechanism units: volts per mechanism rotation, or volts per meter for an elevator or another mechanism that moves in a line. A kP of 4 on an arm means 4 V of output for each full rotation of error, which is about 0.1 V for each 10° off. A feedforward kV of 2 means 2 V for each rotation per second.

YAMS converts your gains to whatever each motor controller wants, so the same numbers behave the same on a SPARK, a Talon, a Nova or an A301. You never multiply by the gear ratio yourself.

Next

Build one: start with the Arm tutorial. Look up an option: SmartMotorControllerConfig.

Last updated